DMU-07

DMG MORI DMU 50 (3rd Generation) · Heidenhain TNC 640 · Bay 2 · Cell C · s/n DMU50-21259

Live machine view
Five-axis cycle
X/Y/Z, the swivelling B trunnion and the C rotary table follow live telemetry; the door opens when the machine stops. Drag to rotate, scroll to zoom.
Alarm
Effectiveness
OEE this shift
Late (14:00–22:00) · 205 of 249 min running
64%

Availability

82.3%

Performance

79.6%

Quality

97.9%

Current job
WO-24136
Harmonic drive housing · RR-8834-B

Pieces

45 / 75

Cycle time

4m 20s

This piece

0s elapsed

Operator

Unattended

Tool

T22 · Ø20 shell mill

Tool life left

5%

Finishes

—

Losses
Downtime by reason
44.2 minutes lost this shift, biggest first.

Setup / first-off

11.9 min

No operator

8.5 min

Tool change

7.7 min

Breakdown

7.6 min

No material

5.4 min

Waiting QA

3.1 min

Quality
Pieces this shift
Ideal 204 s versus actual 256 s per piece.

Good

47

Scrap

1

Rework

0

OEE per hour · %

Queue
Jobs on this machine (4)
The job on the spindle and everything queued behind it, earliest due date first.

WO-24138

Reichl Robotics · RR-8834-B OP30 · Al 6061-T6 · setup 48 min

Queued

0/75 · due 08 Oct 16:09

WO-24136

Brunner Hydraulik · RR-8834-B OP10 · Al 6061-T6 · setup 122 min

Paused

45/75 · due 09 Oct 02:09

WO-24139

High

Reichl Robotics · VO-2075-A OP30 · Invar 36 · setup 61 min

Queued

0/150 · due 10 Oct 06:09

WO-24140

Helvetica Medtech · AD-3310-A OP30 · Al 7075-T6 · setup 109 min

Queued

0/20 · due 10 Oct 13:09

Readings
Live telemetry
Polled every 5 seconds · spindle 19,125 h, service in 726 h

Spindle load

0 %

Spindle speed

0 rpm

Feed rate

0 mm/min

Spindle temp

20.8 °C

Coolant temp

20 °C

Coolant pressure

0 bar

Vibration

0 mm/s

Axis load B

0 %

Axis positions

X

0.0

Y

0.0

Z

0.0

B

0.0

C

0.0

Spindle history
Spindle load, speed and vibration

Spindle load · %

Spindle speed · rpm

Vibration · mm/s

Alarms
Alarms (4)

C axis following error

Alarm 1188 · 10-06 17:59

medium

Air pressure below minimum

Alarm 8830 · 10-06 08:08

low

Door interlock opened during cycle

Alarm 6621 · 10-06 01:29

medium

Workpiece clamping pressure dropped

Alarm 9007 · 10-05 20:10

low